Summary for Test 2020-07-13-25-6

Test performed: CTM 553-1

Project Information

Project IdentifiersProject ID: 213811
DEA: 112T2184
EFIS: 1116000174
DIST-CO-RTE-PM11-SD-5-R38.4/R47.3
Award Date10/29/2018
Closeout Date01/03/2024
Work Description(Alternative Delivery) Construct HOV lanes, soundwalls, culvert rehab, ITS, and bike trail on I-5 . NCC I-5 Highway Improvement.
Location DescriptionIN SAN DIEGO COUNTY IN ENCINITAS AND CARLSBAD FROM SAN ELIJO LAGOON BRIDGE TO 0.3 MILE NORTH OF PALOMAR AIRPORT ROAD OVERCROSSING.
QA Service Level1 (Verified on 12/19/2018)

Sample Information

Sample Taken Date07/13/2020 Sample Unique Key25
Date that the sample was received by the laboratory/organization performing the testing07/13/2020 Sample typeQuality Assurance
A brief description of the sampleRapid Setting Cement The quantity of what the sample constitutes1 bag
From where was the sample collectedJob Site First name of sampler or witnessed byna
Last name of sampler or witnessed byna Title of sampler
Telephone number of sampler Laboratory sample identificationCM204001
Linked DIME Sample ID The fabricator/manufacturer/facility nameC-MAX
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeCementitious BrandCMAX
MillUnknown Type of Cementitious MaterialRapid Set Cement

Test Details

DIME Sample ID: 2020-07-13-25
DIME Test ID: 2020-07-13-25-6
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: CTM 553-1: Method for Testing Thermal Stability of Mortar Made with Hydraulic Cement
Test Release Date: 2020-08-17

Test Results


Input Type: Measured
Tester's full name: Benjamin Lenz
Date of test: 08/06/2020
Cross-sectional area of the specimen: 4 in^2
Age at the time of test: 72 hours
Maximum load at failure of specimen 1, 23 ± 1.7°C for 48h: 11697 lbs
Maximum load at failure of specimen 2, 23 ± 1.7°C for 48h: 10838 lbs
Maximum load at failure of specimen 3, 23 ± 1.7°C for 48h: 10245 lbs
Maximum load at failure of specimen 1, 50 ± 1°C for 48h: 19769 lbs
Maximum load at failure of specimen 2, 50 ± 1°C for 48h: 20738 lbs
Maximum load at failure of specimen 3, 50 ± 1°C for 48h: 21383 lbs
Average of test specimens broken to nearest 50 kPa, 23 ± 1.7°C for 48h: 18850 kPa
Average of test specimens broken to nearest 50 kPa, 50 ± 1°C for 48h: 35560 kPa
Thermal stability ratio: 189
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/17/2020 ✔