Summary for Test 2020-07-13-25-2
Test performed: ASTM C109-16aProject Information
| Project Identifiers | Project ID: 213811 DEA: 112T2184 EFIS: 1116000174 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-5-R38.4/R47.3 |
| Award Date | 10/29/2018 |
| Closeout Date | 01/03/2024 |
| Work Description | (Alternative Delivery) Construct HOV lanes, soundwalls, culvert rehab, ITS, and bike trail on I-5 . NCC I-5 Highway Improvement. |
| Location Description | IN SAN DIEGO COUNTY IN ENCINITAS AND CARLSBAD FROM SAN ELIJO LAGOON BRIDGE TO 0.3 MILE NORTH OF PALOMAR AIRPORT ROAD OVERCROSSING. |
| QA Service Level | 1 (Verified on 12/19/2018) |
Sample Information
| Sample Taken Date | 07/13/2020 | Sample Unique Key | 25 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 07/13/2020 | Sample type | Quality Assurance |
| A brief description of the sample | Rapid Setting Cement | The quantity of what the sample constitutes | 1 bag |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | na |
| Last name of sampler or witnessed by | na | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | CM204001 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | C-MAX | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Cementitious | Brand | CMAX |
|---|---|---|---|
| Mill | Unknown | Type of Cementitious Material | Rapid Set Cement |
Test Details
DIME Sample ID: 2020-07-13-25
DIME Test ID: 2020-07-13-25-2
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Test Release Date: 2020-08-17
Test Results
Will control cubes be used per ASTM C311?: no
Input Type: Measured
Tester's full name: Benjamin Lenz
Date of test: 08/06/2020
Age of specimen: 3 days
The amount of flow : 107 %
The amount of water used : 50.6 %
Compressive strength of 1st specimen : 2731 psi
Compressive strength of 2nd specimen: 2817 psi
Compressive strength of 3rd specimen : 2905 psi
Average Compressive strength (to nearest 10 psi): 2820 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/17/2020 ✔