Summary for Test 2020-07-30-10-4
Test performed: ASTM F606-14aProject Information
| Project Identifiers | Project ID: 210037 DEA: 043G4424 EFIS: 0412000042 |
|---|---|
| DIST-CO-RTE-PM | 04-SF-80-R5.6/7.6 |
| Award Date | 03/22/2018 |
| Closeout Date | 07/24/2023 |
| Work Description | WEST SPAN DAMPER BRACKET A325 BOLT TESTING |
| Location Description | SFOBB WEST SPAN |
| QA Service Level | 1 (Verified on 11/04/2014) |
Sample Information
| Sample Taken Date | 07/30/2020 | Sample Unique Key | 10 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/03/2020 |
| Sample type | Department Acceptance | A brief description of the sample | Bolt Assemblies |
| The quantity of what the sample constitutes | 5@9-1/2", 3@11" | From where was the sample collected | Distributor |
| First name of sampler or witnessed by | Ryan | Last name of sampler or witnessed by | Parr |
| Title of sampler | ASI | Telephone number of sampler | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Bay Bolt | Transportation Laboratory (TL) Number | 741528 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | B373-042-20 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 4821-05, 4821-06 |
|---|---|---|---|
| Heat Number(s) | NU739824, 3088576 | Nut Mfg. Lot Number(s) | 27359-621448003 |
| Washer Mfg. Lot Number(s) | 299421 | Bolt Specification | ASTM A490 |
| Bolt Length(s) | 9-1/2", 11" | Nut Specification | ASTM A194 |
| Washer Specification | ASTM F436 | Finish | Plain |
| Diameter/Size | 1" | Bolt Mfg. Lot Number | 217120A, 563132-2 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2020-07-30-10
DIME Test ID: 2020-07-30-10-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2020-08-04
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 08/04/2020
UTM: 450kip
Temperature: no data
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 2A | 217120A | 1.0000 | 94844 | 421.89 | 10.00 | A490 Bolt | fsaylor |
General comments (publicly viewable) (Max 1000 characters): A490 Bolt
Test Graph
Source: Bluehill Data Point FileTest was verified on 8/4/2020 ✔