Summary for Test 2020-07-28-10-1
Test performed: ASTM F606-14aProject Information
| Project Identifiers | Project ID: 213737 DEA: 07289104 EFIS: 0700021123 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-405-11.9/13.2 |
| Award Date | 01/09/2019 |
| Closeout Date | 07/14/2022 |
| Work Description | Rehabilitate the existing Commercial Vehicle Enforcement Facility. |
| Location Description | LOS ANGELES COUNTY IN CARSON FROM DEL AMO BOULEVARD OVER CROSSING TO VERMONT AVENUE (190TH) UNDER CROSSING. |
| QA Service Level | 1 (Verified on 08/26/2019) |
Sample Information
| Sample Taken Date | 07/28/2020 | Sample Unique Key | 10 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 07/31/2020 | Sample type | Quality Assurance |
| A brief description of the sample | 1 1/4-7 x 3 3/4" A325 HVY HX Bolts, Plain | The quantity of what the sample constitutes | 44 |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Jamie |
| Last name of sampler or witnessed by | Doe | Title of sampler | CALTRANS METS QA INSPECTOR |
| Telephone number of sampler | (916) 838-4405 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Nucor | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | S50-047-20 | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | B418485A N433649B WD6958 |
|---|---|---|---|
| Heat Number(s) | 100893998 | Nut Mfg. Lot Number(s) | n/a |
| Washer Mfg. Lot Number(s) | n/a | Bolt Specification | ASTM A325 |
| Bolt Length(s) | 3 3/4" | Nut Specification | n/a |
| Washer Specification | n/a | Finish | Plain |
| Diameter/Size | 1 1/4-7" | Bolt Mfg. Lot Number | 418485A |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Test Details
DIME Sample ID: 2020-07-28-10
DIME Test ID: 2020-07-28-10-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2020-08-06
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 08/03/2020
UTM: 450kip
Temperature: no data
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1A | 418485A | 1.2500 | 144821 | 644.2 | 6.00 | A325 Wedge Tensile | spaine |
General comments (publicly viewable) (Max 1000 characters): A325 Wedge Tensile
Test Graph
Source: Bluehill Data Point FileTest was verified on 8/6/2020 ✔