Summary for Test 2020-07-30-5-3
Test performed: ASTM A970-15e1Project Information
| Project Identifiers | Project ID: 214841 DEA: 034H1004 EFIS: 0318000176 |
|---|---|
| DIST-CO-RTE-PM | 03-SIE-49-9.2/24.7 |
| Award Date | 05/29/2020 |
| Closeout Date | 07/29/2022 |
| Work Description | INSTALL RETAINING STRUCTURE AND RSP CONCRETE EMBANKMENT. |
| Location Description | SIERRA COUNTY ON ROUTE 49 AT VARIOUS LOCATIONS |
| QA Service Level | 1 (Verified on 03/24/2020) |
Sample Information
| Sample Taken Date | 07/30/2020 | Sample Unique Key | 5 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 07/31/2020 | Sample type | Department Acceptance |
| A brief description of the sample | #6 double headed rebar | The quantity of what the sample constitutes | 22 Pieces, 44 Heads Lot#2 |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Kevin |
| Last name of sampler or witnessed by | Muser | Title of sampler | QA |
| Telephone number of sampler | 9165170532 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Pacific Steel | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | S19-400-20 | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Rebar Heat Number(s) | 65028682 | Head Manufacturer Lot Number(s) | N/A |
| Rebar Size | #6 | Headed Bar Model Name | 555 |
| Size of Head | Reduced Size - 4x | Head Connection Type | Forged |
| Head Shape | Circular | Rebar Manufacturer | Gerdau |
| Head Manufacturer | HRC | Head Fabricator | HRC |
| Material Standard Code | ASTM A706 | Headed Bar Unique ID | Not set |
Test Details
DIME Sample ID: 2020-07-30-5
DIME Test ID: 2020-07-30-5-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2020-08-03
Test Results
Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 08/03/2020
UTM: 400kip
Temperature: 72 f
| Num | Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|
| 1 | 2 | 0.44 | 44241 | 100548 | OK Necking | fsaylor |
General comments (publicly viewable) (Max 1000 characters): OK Necking
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 8/3/2020 ✔