Summary for Test 2020-05-20-44-3
Test performed: AASHTO T283-14Project Information
| Project Identifiers | Project ID: 66667 DEA: JMFPP EFIS: 0019000043 |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for submitting Sample information for JMF Prequalification Program. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 05/20/2020 | Sample Unique Key | 44 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/20/2020 |
| Sample type | Aggregate Prequalification Program | A brief description of the sample | JMF Prequalification Program |
| The quantity of what the sample constitutes | 16 Boxes | From where was the sample collected | Source |
| First name of sampler or witnessed by | Chris | Last name of sampler or witnessed by | Escobar |
| Title of sampler | QC Operations Supervisor | Telephone number of sampler | 2096655586 |
| Laboratory sample identification | 1738350575 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Granite Construction Vernalis | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | Not set | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2020-05-20-44
DIME Test ID: 2020-05-20-44-3
Testing Lab: Granite Construction Company - Tracy
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Test Release Date: 2020-07-31
Test Results
Unit system used?: SI Units
Input Type: Calculated
Tester's full name: Chris Escobar
Date of test: 05/20/2020
| Wet 1 | Wet 2 | Wet 3 | Dry 1 | Dry 2 | Dry 3 | |
|---|---|---|---|---|---|---|
| Treated | ||||||
167 psi | 207 psi | |||||
81 | ||||||
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/31/2020 ✔