Summary for Test 2020-07-20-11-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 214695
DEA: 120R8604
EFIS: 1219000048
DIST-CO-RTE-PM12-ORA-5-28.3/31.8
Award Date04/02/2020
Closeout Date01/04/2021
Work DescriptionCOLD PLANE AC PVMT AND PLACE RHMA.
Location DescriptionORANGE COUNTY IN TUSTIN AND SANTA ANA FROM TUSTIN RANCH ROAD UNDERCROSSING TO GRAND AVENUE UNDERCROSSING
QA Service Level1 (Verified on 12/10/2020)

Sample Information

Sample Taken Date07/20/2020 Sample Unique Key11
Date that the sample was received by the laboratory/organization performing the testing07/28/2020 Sample typeVerification
A brief description of the samplePSUE 1/2" RWMA-G-SP 0.25% Evo The quantity of what the sample constitutes3 Bags Coldfeed aggregate
From where was the sample collectedManufacturer First name of sampler or witnessed byVictor
Last name of sampler or witnessed byPham Title of sampler
Telephone number of sampler Laboratory sample identification0464G-20
Linked DIME Sample ID The fabricator/manufacturer/facility nameR J Noble Orange
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0014/ 91-33-0035
The fabricator's/manufacturer's product name for the sample1/2 RWMA-G-SP The fabricator/manufacturer designation for the sample
The plant number50R003ARSPWEO A detailed description of where the material sample was collectedBelt Cut at RJ Noble Orange Plant
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-07-20-11
DIME Test ID: 2020-07-20-11-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2020-08-03

Test Results


What type of gradation is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: Satish Jain, Sebastian Ferrer
Date of test: 07/29/2020
Cumulative Percent Passing
100 %
100 %
100 %
100 %
95 %
81 %
37 %
22 %
15 %
11 %
8 %
6 %
4.2 %
General comments (publicly viewable) (Max 1000 characters): Combined Virgin Aggregate Gradation

Test was verified on 8/3/2020 ✔