Summary for Test 2018-09-13-11-4
Test performed: CTM 643-April 2020Project Information
| Project Identifiers | Project ID: 212779 DEA: 021H5804 EFIS: 0216000024 |
|---|---|
| DIST-CO-RTE-PM | 02-PLU-70-58.4/R78.4 |
| Award Date | Not set |
| Closeout Date | 10/03/2025 |
| Work Description | Not set |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 01/08/2019) |
Sample Information
| Sample Taken Date | 09/13/2018 | Sample Unique Key | 11 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/26/2018 |
| Sample type | Informational | A brief description of the sample | Sand, Silt, Clay |
| The quantity of what the sample constitutes | not provided | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Dan | Last name of sampler or witnessed by | Curran |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | D77640 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Not applicable | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Not Applicable |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Plu 70 PM 76.3 | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2018-09-13-11
DIME Test ID: 2018-09-13-11-4
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2020-08-18
Test Results
The test method used?: Laboratory Resistivity Test for Soil (pH and Resistivity)
Input Type: Calculated
Tester's full name: Mike Cruz
Date of test: 09/22/2018
Minimum soil resistance of the lab measurement: 9550 Ohms
Soil sample temperature: 21.8 C
Soil box constant: 1
pH of soil: 6.43
Minimum soil resistance corrected to 15.5: 11054 Ohm-cm
Minimum soil resistivity at 15.5: 11054 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/18/2020 ✔