Summary for Test 2018-09-13-10-4

Test performed: CTM 643-April 2020

Project Information

Project IdentifiersProject ID: 212779
DEA: 021H5804
EFIS: 0216000024
DIST-CO-RTE-PM02-PLU-70-58.4/R78.4
Award DateNot set
Closeout Date10/03/2025
Work DescriptionNot set
Location DescriptionNot set
QA Service Level1 (Verified on 01/08/2019)

Sample Information

Sample Taken Date09/13/2018 Sample Unique Key10
Date that the sample was received by the laboratory/organization performing the testing09/14/2018 Sample typeInformational
A brief description of the sampleNative Soil The quantity of what the sample constitutesnot provided
From where was the sample collectedJob Site First name of sampler or witnessed byDan
Last name of sampler or witnessed byCurran Title of sampler
Telephone number of sampler Laboratory sample identificationD77639
Linked DIME Sample ID The fabricator/manufacturer/facility nameNot applicable
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Not Applicable
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedPlu 70 PM 60.0
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2018-09-13-10
DIME Test ID: 2018-09-13-10-4
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2020-08-18

Test Results


The test method used?: Laboratory Resistivity Test for Soil (pH and Resistivity)
Input Type: Calculated
Tester's full name: Mike Cruz
Date of test: 09/14/2018
Minimum soil resistance of the lab measurement: 8050 Ohms
Soil sample temperature: 20.8 C
Soil box constant: 1
pH of soil: 6.39
Minimum soil resistance corrected to 15.5: 9117 Ohm-cm
Minimum soil resistivity at 15.5: 9117 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/18/2020 ✔