Summary for Test 2020-03-12-33-5
Test performed: CTM 229-June 2011Project Information
Project Identifiers | Project ID: 66666 DEA: APP EFIS: 0019000052 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for Aggregate Pre-approval Program (APP). Object Code: 1025. J2 DEA: 912680. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 03/12/2020 | Sample Unique Key | 33 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/17/2020 |
Sample type | Aggregate Prequalification Program | A brief description of the sample | Washed Concrete Sand |
The quantity of what the sample constitutes | 3 Bags | From where was the sample collected | Source |
First name of sampler or witnessed by | Marc | Last name of sampler or witnessed by | Segura |
Title of sampler | QC Rep | Telephone number of sampler | |
Laboratory sample identification | 9541 | Linked DIME Sample ID | 2020-03-12-28 |
The fabricator/manufacturer/facility name | Cemex Redlands | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-36-0068::REDLANDS WASH PLAN (CEMEX) |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
The plant number | Unknown | A detailed description of where the material sample was collected | SOURCE |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | fine |
The concrete mix design number | Unknown | Lot number | Unknown |
Sublot number | Unknown | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2020-03-12-33
DIME Test ID: 2020-03-12-33-5
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: CTM 229-June 2011: Method of Test for Durability Index
Test Release Date: 2020-07-28
Test Results
What test(s) are being run?: Fine durability only
Input Type: Calculated
Tester's full name: Larry Diaz
Date of test: 04/06/2020
Fine durability index: 86
General comments (publicly viewable) (Max 1000 characters): Testing performed by SRL
Test was verified on 7/28/2020 ✔