Summary for Test 2020-07-16-15-2
Test performed: AASHTO T59-16Project Information
| Project Identifiers | Project ID: 215041 DEA: 031J1904 EFIS: 0320000169 |
|---|---|
| DIST-CO-RTE-PM | 03-YUB,YUB/SUT-70,70,99-Var |
| Award Date | 06/08/2020 |
| Closeout Date | 06/27/2022 |
| Work Description | In-kind restoration pvmt. repair w/HMA medium overlay, striping, traffic control, incidental work |
| Location Description | Yubat & Sutter Counties at various locaitons |
| QA Service Level | 1 (Verified on 07/20/2020) |
Sample Information
| Sample Taken Date | 07/16/2020 | Sample Unique Key | 15 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/20/2020 |
| Sample type | Department Acceptance | A brief description of the sample | EMULSION |
| The quantity of what the sample constitutes | 1 jug | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Linda | Last name of sampler or witnessed by | Pidggett |
| Title of sampler | Inspector | Telephone number of sampler | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | vssi | Transportation Laboratory (TL) Number | 788958 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Asphaltic Emulsion | Emulsion Grade | SS-1h |
|---|---|---|---|
| Lot Number | Not set | Sub Lot | Not set |
| Dilution Percentage Rate | Not set |
Test Details
DIME Sample ID: 2020-07-16-15
DIME Test ID: 2020-07-16-15-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T59-16: Standard Method of Test for Emulsified Asphalts (Emulsified Asphalt Residue Evap. (Sec. 7))
Test Release Date: 2020-07-27
Test Results
How many beakers will be used to conduct the test?: 4
Input Type: Measured
Tester's full name: Juan Gomez
Date of test: 07/27/2020
Beaker 1 Mass of beaker, rod, screen (if used), and residue: 447.7 g
Beaker 1 Tare mass of the beaker, rod, and screen (if used): 416.4 g
Beaker 2 Mass of beaker, rod, screen (if used), and residue: 443.7 g
Beaker 2 Tare mass of the beaker, rod, and screen (if used): 412.4 g
Beaker 3 Mass of beaker, rod, screen (if used), and residue: 450.9 g
Beaker 3 Tare mass of the beaker, rod, and screen (if used): 419.6 g
Beaker 4 Mass of beaker, rod, screen (if used), and residue: 453.8 g
Beaker 4 Tare mass of the beaker, rod, and screen (if used): 422.5 g
Beaker 1 Residue: 62.6 %
Beaker 2 Residue: 62.6 %
Beaker 3 Residue: 62.6 %
Beaker 4 Residue: 62.6 %
Percentage of residue: 62.6 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/27/2020 ✔