Summary for Test 2020-07-14-33-19

Test performed: ASTM A370-15

Project Information

Project IdentifiersProject ID: 213598
DEA: 051F75U4
EFIS: 0518000092
DIST-CO-RTE-PM05-MON-101-R36.9/47.7
Award Date01/16/2019
Closeout Date01/11/2024
Work DescriptionCRCP, SEISMIC RETROFIT, BRIDGE WIDENING AND MEDIAN BARRIER
Location DescriptionMONTEREY COUNTY IN AND NEAR KING CITY FROM 0.4 MILE SOUTH OF WILD HORSE ROAD OVERCROSSING TO TEAGUE AVENUE
QA Service Level1 (Verified on 10/11/2018)

Sample Information

Sample Taken Date07/14/2020 Sample Unique Key33
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/13/2020
Sample typeDepartment Acceptance A brief description of the sample1-1/2" 6 x 29" HDG Rod w/ nut & washer
The quantity of what the sample constitutes72 ea. From where was the sample collectedFabricator
First name of sampler or witnessed byJason Last name of sampler or witnessed byGramlick
Title of sampler Telephone number of sampler5104537830
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameStinger Bridge Iron Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormB-3-200-20 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)3092316 Nut Mfg. Lot Number(s)29270-75073143
Washer Mfg. Lot Number(s)1512 Bolt SpecificationF1554
Bolt Length(s)29 Nut SpecificationA194
Washer SpecificationF436 FinishF2329
Diameter/Size1.5 Bolt Mfg. Lot NumberF1554
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2020-07-14-33
DIME Test ID: 2020-07-14-33-19
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2020-07-23

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 07/23/2020
UTM: 67kip
Temperature: 72 f
NumSampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
1130923160.5030.199631879117027.4fsaylor

General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 7/23/2020