Summary for Test 2020-06-15-28-1
Test performed: AASHTO T59-16Project Information
| Project Identifiers | Project ID: 212535 DEA: 031A9204 EFIS: 0300020608 |
|---|---|
| DIST-CO-RTE-PM | 03-SUT-20-5-11.3 |
| Award Date | 06/11/2019 |
| Closeout Date | 12/01/2021 |
| Work Description | SUTTER BYPASS WIDENING AND REHAB |
| Location Description | NEAR YUBA CITY FROM SUTTER BYPASS TO 0.1 MILE WEST OF LYTLE ROAD. |
| QA Service Level | 1 (Verified on 07/23/2018) |
Sample Information
| Sample Taken Date | 06/15/2020 | Sample Unique Key | 28 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 07/17/2020 | Sample type | Department Acceptance |
| A brief description of the sample | EMULSION | The quantity of what the sample constitutes | 1 jug |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | P |
| Last name of sampler or witnessed by | Frazer | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Pacific Northwest Oil - Stockton, CA | |
| Transportation Laboratory (TL) Number | 779026 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Asphaltic Emulsion | Emulsion Grade | SS-1h |
|---|---|---|---|
| Lot Number | Not set | Sub Lot | Not set |
| Dilution Percentage Rate | Not set |
Test Details
DIME Sample ID: 2020-06-15-28
DIME Test ID: 2020-06-15-28-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T59-16: Standard Method of Test for Emulsified Asphalts (Residue and Oil Distillate (Sec. 6))
Test Release Date: 2020-07-21
Test Results
What parameters are being calculated?: Percentage of oil residue
Is this a polymer-modified emulsion: No
Input Type: Measured
Tester's full name: Juan Gomez
Date of test: 07/20/2020
Mass of the distillation pot, accessories, and reside after the test: 2391.9 g
Mass of distillation pot and accessories before test: 2278.3 g
Correction Factor: 1.5
Mass of the distallation pot, accessories, and reside after the test w/ correction factor: 2393.4 g
Percentage of oil residue: 57.5 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/21/2020 ✔