Summary for Test 2020-07-14-1-1
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 214702 DEA: 030F2864 EFIS: 0320000123 |
---|---|
DIST-CO-RTE-PM | 03-SAC-99-7.92 / 8.4 |
Award Date | 06/24/2020 |
Closeout Date | 11/28/2023 |
Work Description | Remove and replace Consumnes River and Consumnes River Overflow bridge |
Location Description | Sacramento County |
QA Service Level | 1 (Verified on 04/20/2020) |
Sample Information
Sample Taken Date | 07/14/2020 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/15/2020 |
Sample type | Quality Assurance | A brief description of the sample | #8 hoops |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Frederic | Last name of sampler or witnessed by | Aboujaoude |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | CMC Etiwanda | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L147-039-20 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Rebar Heat Number(s) | 3095922 |
Hoop Manufacturer Lot Number(s) | 19 | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Size | #8 |
Diameter of Hoop | 6'-2" | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | CMC |
Welding Company | CMC Etiwanda | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2020-07-14-1
DIME Test ID: 2020-07-14-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2020-07-21
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 07/21/2020
UTM: 400kip
Temperature: 72 f
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 1 | 19 | 8/25mm | 0.79 | 74554.63 | 94373 | OK Necking | fsaylor |
General comments (publicly viewable) (Max 1000 characters): OK Necking
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 7/21/2020 ✔