Summary for Test 2010-07-07-1-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 213551 DEA: 080K2934 EFIS: 0812000100 |
---|---|
DIST-CO-RTE-PM | 08-SBD-10-R36.8/R39.2 |
Award Date | 11/09/2018 |
Closeout Date | 09/15/2021 |
Work Description | PAVEMENT REHABILITATION AND CONTINUOUSLY REINFORCED CONCRETE PAVEMENT |
Location Description | SAN BERNARDINO COUNTY IN YUCAIPA FROM 0.2 MILE WEST OF LIVE OAK CANYON ROAD TO COUNTY LINE ROAD UNDERCROSSING |
QA Service Level | 1 (Verified on 12/31/2018) |
Sample Information
Sample Taken Date | 07/07/2010 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/10/2020 |
Sample type | Department Acceptance | A brief description of the sample | 3/4" RHMA-G PG64-RB (0.5% LAS) |
The quantity of what the sample constitutes | 1250 Tons out | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | QC | Last name of sampler or witnessed by | QC |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Matich-Cabazon | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | 1 |
Sublot number | 4 | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2010-07-07-1
DIME Test ID: 2010-07-07-1-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2020-07-16
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Angelito Villegas
Date of test: 07/11/2020
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: no data g
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): no data %
Moisture Content: no data %
Temperature Compensation Factor: no data
Test Temperature: no data F
Corrected Asphalt Binder Content: 8.08 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/16/2020 ✔