Summary for Test 2020-06-25-35-3

Test performed: ASTM D412-06a-re13

Project Information

Project IdentifiersProject ID: 214625
DEA: 120R5404
EFIS: 1218000113
DIST-CO-RTE-PM12-ORA-5-1.6/33.1
Award Date02/27/2020
Closeout Date07/29/2021
Work DescriptionMethacrylate deck seal treatment and polyester concrete overlay
Location DescriptionFOR CONSTRUCTION ON STATE HIGHWAY IN ORANGE COUNTY AT VARIOUS LOCATIONS FROM EL CAMINO REAL UNDERCROSSING TO MAIN STREET OVERCROSSING
QA Service Level1 (Verified on 06/16/2020)

Sample Information

Sample Taken Date06/25/2020 Sample Unique Key35
Date that the sample was received by the laboratory/organization performing the testing06/30/2020 Sample typeQuality Assurance
A brief description of the sample3.75 elastomeric joint seal The quantity of what the sample constitutes550 ft
From where was the sample collectedManufacturer First name of sampler or witnessed byDavid
Last name of sampler or witnessed bySimon Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameWatson Bowman
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM2 - Type B Elastomeric Joint Seal Mfg. Lot Number(s)2620268
Manufacturer(s)Watson Bowman Temperature72
Humidity50 Comments
Joint Seal Size3.75"

Test Details

DIME Sample ID: 2020-06-25-35
DIME Test ID: 2020-06-25-35-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM D412-06a-re13: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Test Release Date: 2020-07-22

Test Results


Number of specimens tested: 3
Unit of the Ultimate Tensile Values: psi
Input Type: Calculated
Tester's full name: spaine
Date of test: 07/15/2020
UTM: 2kip
Humidity: 50.00 %
Temperature: 72 F
Sample 1 Median Thickness: 0.072
Sample 1 Thickness all Within 0.003 inch?: Yes
Sample 1 Ultimate Tensile: 2269.02
Sample 1 Elongation (350% Min): Pass
Sample 2 Median Thickness: 0.068
Sample 2 Thickness all Within 0.003 inch?: Yes
Sample 2 Ultimate Tensile: 2187.78
Sample 2 Elongation (350% Min): Pass
Sample 3 Median Thickness: 0.071
Sample 3 Thickness all Within 0.003 inch?: Yes
Sample 3 Ultimate Tensile: 2159.25
Sample 3 Elongation (350% Min): Pass
Median of the Ultimate Tensile Values: 2187.8 psi
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point File
Test graph for Sample 2

Source: Bluehill Data Point File
Test graph for Sample 1

Source: Bluehill Data Point File
Test graph for Sample 3

Test was verified on 7/22/2020 ✔