Summary for Test 2020-05-20-35-2

Test performed: AASHTO T335-09r13

Project Information

Project IdentifiersProject ID: 66666
DEA: APP
EFIS: 0019000052
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for Aggregate Pre-approval Program (APP). Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date05/20/2020 Sample Unique Key35
Date that the sample was received by the laboratory/organization performing the testing05/21/2020 Sample typeAggregate Prequalification Program
A brief description of the sampleHMA - 1/4" Bin The quantity of what the sample constitutes3 Buckets
From where was the sample collectedSource First name of sampler or witnessed byPlant
Last name of sampler or witnessed byTechnician Title of sampler
Telephone number of sampler Laboratory sample identification20-0087
Linked DIME Sample ID The fabricator/manufacturer/facility nameGraniterock - AR Wilson Quarry
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-35-0012::A.R. WILSON QUARRY
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedStockpile
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1/4 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-05-20-35
DIME Test ID: 2020-05-20-35-2
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Test Release Date: 2020-07-01

Test Results


Method: 1 - Combined Fracture Determination
Aggregate Size and Fracture Type: Coarse 1 and 2 Faced
Input Type: Measured
Tester's full name: Bang Nguyen
Date of test: 06/17/2020
Mass of fractured, coarse, 2 faced particles tested: 211.8 g
Mass of questionable, coarse, 2 faced particles tested: 0 g
Mass of unfractured, coarse, 2 faced particles tested: 0 g
Mass of fractured, coarse, 1 faced particles tested: 211.8 g
Mass of questionable, coarse, 1 faced particles tested: 0 g
Mass of unfractured, coarse, 1 faced particles tested: 0 g
Percentage of questionable, coarse, 2 faced particles tested: 0 %
Percentage of questionable, coarse, 1 faced particles tested: 0 %
Percentage of fractured, coarse, 2 faced particles tested: 100 %
Percentage of fractured, coarse, 1 faced particles tested: 100 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/1/2020