Summary for Test 2020-03-12-23-5
Test performed: CTM 206-October 2011Project Information
| Project Identifiers | Project ID: 66666 DEA: APP EFIS: 0019000052 |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for submitting Sample information for Aggregate Pre-approval Program (APP). Object Code: 1025. J2 DEA: 912680. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 03/12/2020 | Sample Unique Key | 23 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 03/17/2020 | Sample type | Aggregate Prequalification Program |
| A brief description of the sample | 1-1/2 PCC Aggregates | The quantity of what the sample constitutes | 4 Bags |
| From where was the sample collected | Source | First name of sampler or witnessed by | Marc |
| Last name of sampler or witnessed by | Segura | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | 9535 | |
| Linked DIME Sample ID | 2020-03-11-25 | The fabricator/manufacturer/facility name | Cemex Lytle Creek |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-36-0040::LYTLE CREEK |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Stockpile | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1-1/2 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2020-03-12-23
DIME Test ID: 2020-03-12-23-5
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: CTM 206-October 2011: Method of Test for Specific Gravity and Absorption of Coarse Aggregate
Test Release Date: 2020-06-30
Test Results
How will the aggregate be used?: portland cement
Input Type: Measured
Tester's full name: Ryan Kester
Date of test: 04/21/2020
Mass of Sample + Container (in water): 3362.0 grams
Mass of Container (in water): 0.0 grams
Mass of Saturated Surface Dry Sample: 5398.0 grams
Mass of Oven Dry Sample: 5329.0 grams
Mass of Sample (in water): 3362 grams
Mass of Water Absorbed: 69 grams
% Water Absorbed: 1.3 %
Bulk Saturated Surface Dry Specific Gravity: 2.65
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/30/2020 ✔