Summary for Test 2020-06-19-6-1
Test performed: ASTM C39-10Project Information
| Project Identifiers | Project ID: 214422 DEA: 040J6424 EFIS: 0414000476 |
|---|---|
| DIST-CO-RTE-PM | 04-SON-101-32.8/R54.2 |
| Award Date | 12/24/2019 |
| Closeout Date | 01/03/2025 |
| Work Description | CRACK, SEAT AND OVERLAY WITH RHMA AND HMA, AND REPLACE CULVERTS. |
| Location Description | SONOMA COUNTY AT VARIOUS LOCATIONS FROM LIMERICK LANE OVERCROSSING TO ROUTE 101/128 SEPARATION |
| QA Service Level | 1 (Verified on 09/23/2019) |
Sample Information
| Sample Taken Date | 06/19/2020 | Sample Unique Key | 6 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 06/20/2020 | Sample type | Quality Control |
| A brief description of the sample | 6x12 concrete cylinders | The quantity of what the sample constitutes | 2 6x12 Cylinders |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Mark Patrick |
| Last name of sampler or witnessed by | Baddu | Title of sampler | QC Inspector |
| Telephone number of sampler | Laboratory sample identification | 6-19-20-B4 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Con-Fab California, LLC | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | State Route 101 | |
| Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | VER-85LV |
|---|---|---|---|
| The truck number from where the sample was collected | 3rd | The batch plant ticket number from where the sample was collected | 1853 |
| Concrete batch plant | BP1 | The fabricator/manufacturer designation for the sample | Unknown |
| A detailed description of where the material sample was collected | Bed 4, 3rd Truck | Where the material sample would have been placed if not sampled | Casting Bed |
| From Lot No. | Unknown | Bag Lot No. | Unknown |
Test Details
DIME Sample ID: 2020-06-19-6
DIME Test ID: 2020-06-19-6-1
Testing Lab: Con-Fab California Corporation - Lathrop
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2020-06-22
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Danny Cabias
Date of test: 06/20/2020
Capped in accordance with?: ASTM C1231
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 141500 lb
Maximum load on cylinder 2: 142000 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 1 days
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength (to nearest 10 psi): 5010 psi
General comments (publicly viewable) (Max 1000 characters): 1st Break: 5005 psi, 2nd Break: 5022 psi, AVERAGE: 5013 psi
Test was verified on 6/22/2020 ✔