Summary for Test 2020-06-03-17-10
Test performed: CTM 202-November 2011Project Information
| Project Identifiers | Project ID: 214523 DEA: 07302504 EFIS: 0713000479 |
|---|---|
| DIST-CO-RTE-PM | 07-VEN-23-R3.3/R11.5 |
| Award Date | 02/06/2020 |
| Closeout Date | 12/10/2024 |
| Work Description | PLACE HMA AND JPCP AND INDIVIDUAL SLAB REPLACEMENT. |
| Location Description | VENTURA COUNTY FROM ROUTE 101/23 SEPARATION TO NEW LOS ANGELES AVENUE UNDERCROSSING |
| QA Service Level | 1 (Verified on 03/17/2020) |
Sample Information
| Sample Taken Date | 06/03/2020 | Sample Unique Key | 17 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/15/2020 |
| Sample type | Verification | A brief description of the sample | 3/4" HMA -A-SP R15 0.50%LAS Agg. & Rap |
| The quantity of what the sample constitutes | 10 bags of Agg. & 2 bags of Rap | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Vulcan Sun Valley | Last name of sampler or witnessed by | QC |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | 0337A-20 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Vulcan Sun Valley | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-19-0017, 91-19-0019, 91-19-0021 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
| The plant number | 220831 SVA LTR | A detailed description of where the material sample was collected | Belt Cut From Vulcan Sun Valley |
| Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 3/4 inch |
| The concrete mix design number | Unknown | Lot number | Unknown |
| Sublot number | Unknown | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2020-06-03-17
DIME Test ID: 2020-06-03-17-10
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2020-06-24
Test Results
What size aggregate is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Sebastian Ferrer, Satish Jain
Date of test: 06/16/2020
| Sieve Size | Cumulative Percent Passing | |||||
|---|---|---|---|---|---|---|
| 100 % | ||||||
| 100 % | ||||||
| 100 % | ||||||
| 100 % | ||||||
| 100 % | ||||||
| 99 % | ||||||
| 85 % | ||||||
| 72 % | ||||||
| 47 % | ||||||
| 34 % | ||||||
| 25 % | ||||||
| 19 % | ||||||
| 11 % | ||||||
| 6 % | ||||||
| 3.1 % | ||||||
General comments (publicly viewable) (Max 1000 characters): Combined Virgin Aggregate/RAP Gradation w/Correlation Factors Applied
Test was verified on 6/24/2020 ✔