Summary for Test 2020-06-03-17-8

Test performed: AASHTO T304-11

Project Information

Project IdentifiersProject ID: 214523
DEA: 07302504
EFIS: 0713000479
DIST-CO-RTE-PM07-VEN-23-R3.3/R11.5
Award Date02/06/2020
Closeout Date12/10/2024
Work DescriptionPLACE HMA AND JPCP AND INDIVIDUAL SLAB REPLACEMENT.
Location DescriptionVENTURA COUNTY FROM ROUTE 101/23 SEPARATION TO NEW LOS ANGELES AVENUE UNDERCROSSING
QA Service Level1 (Verified on 03/17/2020)

Sample Information

Sample Taken Date06/03/2020 Sample Unique Key17
Date that the sample was received by the laboratory/organization performing the testing06/15/2020 Sample typeVerification
A brief description of the sample3/4" HMA -A-SP R15 0.50%LAS Agg. & Rap The quantity of what the sample constitutes10 bags of Agg. & 2 bags of Rap
From where was the sample collectedManufacturer First name of sampler or witnessed byVulcan Sun Valley
Last name of sampler or witnessed byQC Title of sampler
Telephone number of sampler Laboratory sample identification0337A-20
Linked DIME Sample ID The fabricator/manufacturer/facility nameVulcan Sun Valley
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0017, 91-19-0019, 91-19-0021
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant number220831 SVA LTR A detailed description of where the material sample was collectedBelt Cut From Vulcan Sun Valley
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-06-03-17
DIME Test ID: 2020-06-03-17-8
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Test Release Date: 2020-06-24

Test Results


What test method is performed?: Method A
Input Type: Calculated
Tester's full name: Satish Jain
Date of test: 06/17/2020
Bulk dry specific gravity: 2.636
Average uncompacted voids: 45.0 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/24/2020 ✔