Summary for Test 2020-06-02-20-4
Test performed: AASHTO T269-14Project Information
| Project Identifiers | Project ID: 213942 DEA: 051F7004 EFIS: 0514000055 |
|---|---|
| DIST-CO-RTE-PM | 05-MON-101-73.1/87.3 |
| Award Date | 05/14/2019 |
| Closeout Date | 08/23/2021 |
| Work Description | REPLACE CONCRETE PANEL AND RESURFACE HMA PAVEMENT. |
| Location Description | MONTEREY COUNTY NEAR CHUALAR FROM 0.5 MILE NORTH OF NORTH GONZALES OVERCROSSING TO EAST MARKET STREET UNDERCROSSING |
| QA Service Level | 1 (Verified on 07/10/2019) |
Sample Information
| Sample Taken Date | 06/02/2020 | Sample Unique Key | 20 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/15/2020 |
| Sample type | Verification | A brief description of the sample | Boxes of RHMA-G |
| The quantity of what the sample constitutes | One JMF Renewal | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Wesley | Last name of sampler or witnessed by | Rider |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Graniterock Aromas Batch | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | Unknown |
| Sublot number | Unknown | HMA Mix Number | Not set |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2020-06-02-20
DIME Test ID: 2020-06-02-20-4
Testing Lab: CT D05 - San Luis Obispo District Laboratory
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Test Release Date: 2020-06-18
Test Results
Number of tests: 3
Is the sample lab compacted or field compacted?:
Input Type: Measured
Tester's full name: E. Atkins
Date of test: 06/16/2020
| 1 | 2 | 3 | ||||
|---|---|---|---|---|---|---|
| 2.404 | 2.405 | 2.395 | ||||
| 2.489 | ||||||
3.4 % | 3.4 % | 3.8 % | ||||
3.5 % | ||||||
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/18/2020 ✔