Summary for Test 2020-05-29-30-1
Test performed: CTM 368-November 2010Project Information
Project Identifiers | Project ID: 66667 DEA: JMFPP EFIS: 0019000043 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for JMF Prequalification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 05/29/2020 | Sample Unique Key | 30 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/29/2020 |
Sample type | Verification | A brief description of the sample | Lab Mix for CTM 368 |
The quantity of what the sample constitutes | Lab Mix | From where was the sample collected | Other |
First name of sampler or witnessed by | Danilo | Last name of sampler or witnessed by | Ramirez |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Made in D5 Lab | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | OGFC |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | Unknown |
Sublot number | Unknown | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2020-05-29-30
DIME Test ID: 2020-05-29-30-1
Testing Lab: CT D05 - San Luis Obispo District Laboratory
Test Method: CTM 368-November 2010: Method of Test for Optimum Bitumen Content (OBC) for Open Graded Asphalt Concrete
Test Release Date: 2020-06-17
Test Results
What type of OBC Mix is this?: Unmodified asphalt
Input Type: Calculated
Tester's full name: D. Ramirez
Date of test: 06/15/2020
Draindown at ABR sample 1
: 0.0 g
Draindown at ABR sample 2: 0.0 g
Draindown at ABR sample 3: 0.0 g
Average Draindown at ABR: 0.0 g
Draindown at ABR -0.7% sample 1: 0.0 g
Draindown at ABR -0.7% sample 2: 0.0 g
Draindown at ABR -0.7% sample 3: 0.0 g
Average Draindown at ABR -0.7% : 0.0 g
Draindown at ABR +0.7% sample1: 0.0 g
Draindown at ABR +0.7% sample2: 0.0 g
Draindown at ABR +0.7% sample3: 0.0 g
Average Draindown at ABR +0.7%: 0.0 g
OBC=OBC1: 5.20 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/17/2020 ✔