Summary for Test 2020-05-07-18-3
Test performed: AASHTO T96-02r10Project Information
| Project Identifiers | Project ID: 212899 DEA: 051C6704 EFIS: 0512000194 |
|---|---|
| DIST-CO-RTE-PM | 05-SCR-17-0.2-0.5 |
| Award Date | 02/08/2019 |
| Closeout Date | 09/23/2022 |
| Work Description | PASATIEMPO RETAINING WALL - |
| Location Description | IN SANTA CRUZ FROM 0.5 MILE TO 0.3 MILES SOUTH OF PASATIEMPO OVERCROSSING |
| QA Service Level | 1 (Verified on 04/01/2019) |
Sample Information
| Sample Taken Date | 05/07/2020 | Sample Unique Key | 18 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 05/29/2020 | Sample type | Verification |
| A brief description of the sample | Bags of Aggregate | The quantity of what the sample constitutes | One JMF Verification |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Doug |
| Last name of sampler or witnessed by | Lemon | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Graniterock Aromas | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Unknown |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
| The plant number | Unknown | A detailed description of where the material sample was collected | 91-35-0012 |
| Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 1/2 inch |
| The concrete mix design number | Unknown | Lot number | Unknown |
| Sublot number | Unknown | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2020-05-07-18
DIME Test ID: 2020-05-07-18-3
Testing Lab: CT D05 - San Luis Obispo District Laboratory
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Test Release Date: 2020-06-17
Test Results
Input Type: Calculated
Tester's full name: QC
Date of test: 05/19/2020
Grading designation: C
Percent loss after 100 revolutions: 9 %
Percent loss after 500 revolutions: 36 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/17/2020 ✔