Summary for Test 2020-04-20-32-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 214589
DEA: 020J1604
DIST-CO-RTE-PM02-PLU-284-0.0/8.3
Award Date02/11/2020
Closeout Date10/06/2020
Work DescriptionPLACE HMA (TYPE A), PRECOATED AGGREGATE (SEAL COAT), HMA (LEVELING).
Location DescriptionPLUMAS COUNTY NEAR CHILCOOT FROM ROUTE 70 TO 1 MILE NORTH OF LITTLE LAST CHANCE CREEK BRIDGE NUMBER 09-0072
QA Service Level1 (Verified on 01/22/2020)

Sample Information

Sample Taken Date04/20/2020 Sample Unique Key32
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/21/2020
Sample typeVerification A brief description of the sample1/2-inch Type A HMA (eq. PG 64-28 M) 25.0 RAP, 1.0 Lime
The quantity of what the sample constitutesJMF Verification From where was the sample collectedManufacturer
First name of sampler or witnessed byJimmy Last name of sampler or witnessed byMontana
Title of sampler Telephone number of sampler
Laboratory sample identificationD78404 Linked DIME Sample ID
The fabricator/manufacturer/facility nameWard Lake Plant Transportation Laboratory (TL) Number733179
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot numberUnknown
Sublot numberUnknown HMA Mix NumberNot set

Test Details

DIME Sample ID: 2020-04-20-32
DIME Test ID: 2020-04-20-32-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2020-06-18

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Ward Jenkins
Date of test: 06/16/2020
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1597.4 g
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): 0.66 %
Moisture Content: 0 %
Temperature Compensation Factor: no data
Test Temperature: 1000 F
Corrected Asphalt Binder Content: 5.16 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/18/2020