Summary for Test 2014-10-23-14-4

Test performed: CTM 214-August 2010

Project Information

Project IdentifiersProject ID: 208869
DEA: 08368504
EFIS: 0800000628
DIST-CO-RTE-PM08-SBD-15-177.3/181.1
Award Date10/14/2013
Closeout Date07/27/2023
Work DescriptionCONSTRUCT COMMERCIAL VEHICLE ENFORCEMENT FACILITY (CVEF)
Location DescriptionSAN BERNARDINO COUNTY FROM 1.2 MILES NORTH OF NIPTON ROAD OVERCROSSING TO 0.5 MILE SOUTH OF YATES WELL ROAD OVERCROSSING
QA Service Level1 (Verified on 10/08/2013)

Sample Information

Sample Taken Date10/23/2014 Sample Unique Key14
Date that the sample was received by the laboratory/organization performing the testing10/24/2014 Sample typeAnnual Source Testing
A brief description of the sampleOne and a half inch PCC Aggregates The quantity of what the sample constitutes10 buckets
From where was the sample collectedOther First name of sampler or witnessed byUnknown
Last name of sampler or witnessed byUnknown Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identification4287B
Linked DIME Sample ID0 The fabricator/manufacturer/facility nameCal Portland Aggregate Industries NV
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Unknown
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedCal Portland Aggregate Industries
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1-1/2 inch
The concrete mix design number Lot numberNot set
Sublot numberNot set Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2014-10-23-14
DIME Test ID: 2014-10-23-14-4
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 214-August 2010: Method of Test for Soundness of Aggregates by Use of Sodium Sulfate
Test Release Date: 2015-02-20

Test Results


What size aggregate is being tested?: Coarse Aggregate
Input Type: Calculated
Tester's full name: Nemencio Daof
Date of test: 11/14/2014
Percentage Loss of material retained on 2 x 1 ½ in. sieve: no data
Percentage Loss of material retained on 1 ½ x 1 in. sieve: no data
Percentage Loss of material retained on 1 x ¾ in. sieve: no data
Percentage Loss of material retained on ¾ x ½ in. sieve: no data
Percentage Loss of material retained on ½ x ⅜ in. sieve: no data
Percentage Loss of material retained on ⅜ in. x #4 sieve: no data
Percentage Loss of material retained on 2 in. through 1 1/2 in. sieve: no data
Percentage Loss of material retained on 1 in. through 3/4 in. sieve: no data
Percentage Loss of material retained on 3/4 in. through #4 sieve: no data
Weighted Average Percent Loss of Coarse Aggregate: 0.3 %
Batch Soundness Loss of Coarse Aggregate (2 1/2 in maximum): no data
Batch Soundness Loss of Coarse Aggregate (1 1/2 in maximum): no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/20/2015 ✔