Summary for Test 2020-06-05-16-4
Test performed: ASTM A970-15e1Project Information
Project Identifiers | Project ID: 213229 DEA: 050A0504 EFIS: 0500000007 |
---|---|
DIST-CO-RTE-PM | 05-SB-1-15.6 |
Award Date | 12/14/2018 |
Closeout Date | 08/17/2022 |
Work Description | BRIDGE REPLACEMENT, RETAINING WALL AND FISH PASSAGE. |
Location Description | SANTA BARBARA COUNTY NEAR LOMPOC AT SALSIPUEDES CREEK BRIDGE |
QA Service Level | 1 (Verified on 03/23/2018) |
Sample Information
Sample Taken Date | 06/05/2020 | Sample Unique Key | 16 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/08/2020 |
Sample type | Quality Assurance | A brief description of the sample | HRC 670L End Anchors |
The quantity of what the sample constitutes | 27 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Bernardo | Last name of sampler or witnessed by | Hernandez |
Title of sampler | TE Civil | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | HRC | Transportation Laboratory (TL) Number | 760210 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Production Testing |
---|---|---|---|
Rebar Heat Number(s) | 1712924 | Head Manufacturer Lot Number(s) | 10-19-05-19 |
Rebar Size | #10 | Headed Bar Model Name | 670L |
Size of Head | Full Size - 9x | Head Connection Type | |
Head Shape | Circular | Rebar Manufacturer | Vinton Steel |
Head Manufacturer | HRC | Head Fabricator | HRC |
Material Standard Code | ASTM A706 | Headed Bar Unique ID | Not set |
Test Details
DIME Sample ID: 2020-06-05-16
DIME Test ID: 2020-06-05-16-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2020-06-09
Test Results
Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 06/09/2020
UTM: 400kip
Temperature: 72 f
Num | Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By |
---|---|---|---|---|---|---|
1 | 1 | 1.27 | 136966 | 107848 | Broke at Head | fsaylor |
General comments (publicly viewable) (Max 1000 characters): Broke at Head
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 6/9/2020 ✔