Summary for Test 2020-06-05-16-1
Test performed: ASTM A970-15e1Project Information
| Project Identifiers | Project ID: 213229 DEA: 050A0504 EFIS: 0500000007 |
|---|---|
| DIST-CO-RTE-PM | 05-SB-1-15.6 |
| Award Date | 12/14/2018 |
| Closeout Date | 08/17/2022 |
| Work Description | BRIDGE REPLACEMENT, RETAINING WALL AND FISH PASSAGE. |
| Location Description | SANTA BARBARA COUNTY NEAR LOMPOC AT SALSIPUEDES CREEK BRIDGE |
| QA Service Level | 1 (Verified on 03/23/2018) |
Sample Information
| Sample Taken Date | 06/05/2020 | Sample Unique Key | 16 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/08/2020 |
| Sample type | Quality Assurance | A brief description of the sample | HRC 670L End Anchors |
| The quantity of what the sample constitutes | 27 | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Bernardo | Last name of sampler or witnessed by | Hernandez |
| Title of sampler | TE Civil | Telephone number of sampler | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | HRC | Transportation Laboratory (TL) Number | 760210 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Rebar Heat Number(s) | 1712924 | Head Manufacturer Lot Number(s) | 10-19-05-19 |
| Rebar Size | #10 | Headed Bar Model Name | 670L |
| Size of Head | Full Size - 9x | Head Connection Type | |
| Head Shape | Circular | Rebar Manufacturer | Vinton Steel |
| Head Manufacturer | HRC | Head Fabricator | HRC |
| Material Standard Code | ASTM A706 | Headed Bar Unique ID | Not set |
Test Details
DIME Sample ID: 2020-06-05-16
DIME Test ID: 2020-06-05-16-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2020-06-09
Test Results
Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 06/09/2020
UTM: 400kip
Temperature: 72 f
| Num | Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|
| 1 | 1 | 1.27 | 136361 | 107371 | Broke at Head | fsaylor |
General comments (publicly viewable) (Max 1000 characters): Broke at Head
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 6/9/2020 ✔