Summary for Test 2020-04-20-17-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 214589
DEA: 020J1604
DIST-CO-RTE-PM02-PLU-284-0.0/8.3
Award Date02/11/2020
Closeout Date10/06/2020
Work DescriptionPLACE HMA (TYPE A), PRECOATED AGGREGATE (SEAL COAT), HMA (LEVELING).
Location DescriptionPLUMAS COUNTY NEAR CHILCOOT FROM ROUTE 70 TO 1 MILE NORTH OF LITTLE LAST CHANCE CREEK BRIDGE NUMBER 09-0072
QA Service Level1 (Verified on 01/22/2020)

Sample Information

Sample Taken Date04/20/2020 Sample Unique Key17
Date that the sample was received by the laboratory/organization performing the testing04/21/2020 Sample typeVerification
A brief description of the sample3/4-inch Untreated Sized Virgin Aggregate The quantity of what the sample constitutesJMF Verification
From where was the sample collectedSource First name of sampler or witnessed byJimmy
Last name of sampler or witnessed byMontana Title of sampler
Telephone number of sampler Laboratory sample identificationD78409A
Linked DIME Sample ID The fabricator/manufacturer/facility nameWard Lake Pit
Transportation Laboratory (TL) Number733180 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-18-0008::WARD LAKE PIT
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedSized Untreated Aggregate Stockpile
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberJMF 20-03-S1a Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-04-20-17
DIME Test ID: 2020-04-20-17-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2020-06-09

Test Results


What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): Yes
Has the fine aggregate sample been reduced?: No
Input Type: Measured
Tester's full name: Dennis Hickey
Date of test: 04/22/2020
Cumulative Mass RetainedCumulative Percent Passing
7305.6 grams
grams %
0.0 grams100 %
0.0 grams100 %
803.0 grams89 %
5156.0 grams29.4 %
6701.0 grams8.3 %
7138 grams2.3 %
7161.0 grams2 %
13.5 grams1.8 %
19.1 grams1.7 %
23.2 grams1.7 %
29.0 grams1.6 %
40.8 grams1.4 %
60.3 grams1.17 %
grams
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/9/2020 ✔