Summary for Test 2020-04-15-19-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 214322
DEA: 021H74U4
EFIS: 0218000043
DIST-CO-RTE-PM02-TEH-36-87.8/89.1
Award Date10/11/2019
Closeout Date09/23/2020
Work DescriptionCURVE REALIGNMENT AND EXTENDING THE TRUCK CLIMBING LANE.
Location DescriptionTEHAMA COUNTY NEAR MINERAL FROM 0.1 MILE TO 1.5 MILES EAST OF ROUTE 89
QA Service Level1 (Verified on 09/16/2019)

Sample Information

Sample Taken Date04/15/2020 Sample Unique Key19
Date that the sample was received by the laboratory/organization performing the testing04/15/2020 Sample typeVerification
A brief description of the sample3/4-inch Type A HMA (PG 64-28 M), 15.0 RAP, 1.0 Lime The quantity of what the sample constitutesJMF Verification
From where was the sample collectedManufacturer First name of sampler or witnessed byCindy
Last name of sampler or witnessed byBryant Title of sampler
Telephone number of sampler Laboratory sample identificationD78384
Linked DIME Sample ID The fabricator/manufacturer/facility nameOrland Plant
Transportation Laboratory (TL) Number853429 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot numberUnknown
Sublot numberUnknown HMA Mix NumberNot set
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2020-04-15-19
DIME Test ID: 2020-04-15-19-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2020-06-08

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Ward Jenkins
Date of test: 06/03/2020
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2063.7 g
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): 0.67 %
Moisture Content: 0.00 %
Temperature Compensation Factor: no data
Test Temperature: 1000 F
Corrected Asphalt Binder Content: 4.83 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/8/2020 ✔