Summary for Test 2020-04-03-32-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 214190
DEA: 024G41U4
EFIS: 0218000047
DIST-CO-RTE-PM02-SIS,SIS-5-Var
Award Date08/26/2019
Closeout Date11/24/2021
Work DescriptionREPLACE REINFORCED CONCRETE BRIDGES & CONSTRUCT RETAINING WALL.
Location DescriptionSHASTA AND SISKIYOU COUNTIES ABOUT 7 MILES NORTH OF POLLARD FLAT FROM 0.8 MILE SOUTH TO 0.7 MILE NORTH OF SIMS ROAD UNDERCROSSING AND FROM 0.6 MILE SOUTH OF CASTLE CRAGS DRIVE UNDERCROSSING TO 0.2 MILE SOUTH OF SOUTH DUNSMUIR UNDERCROSSING
QA Service Level1 (Verified on 07/09/2019)

Sample Information

Sample Taken Date04/03/2020 Sample Unique Key32
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/10/2020
Sample typeDepartment Acceptance A brief description of the sample3/4-inch Type A HMA (eq. PG 64-16), 1.1 Lime, 23.6 RAP
The quantity of what the sample constitutes6 tons From where was the sample collectedJob Site
First name of sampler or witnessed byShirley Last name of sampler or witnessed byMcAllister
Title of samplerTET Telephone number of sampler
Laboratory sample identificationD78381 Linked DIME Sample ID
The fabricator/manufacturer/facility nameFawndale Rock and Asphalt - Redding, CA Transportation Laboratory (TL) Number991022
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot numberUnknown
Sublot numberUnknown HMA Mix NumberNot set

Test Details

DIME Sample ID: 2020-04-03-32
DIME Test ID: 2020-04-03-32-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2020-05-29

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Colt Sweeny
Date of test: 04/14/2020
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2100.2 g
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): 0.38 %
Moisture Content: 0 %
Temperature Compensation Factor: no data
Test Temperature: 1000 F
Corrected Asphalt Binder Content: 4.62 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/29/2020