Summary for Test 2020-03-04-21-2
Test performed: CTM 202-November 2011Project Information
Project Identifiers | Project ID: 66666 DEA: APP EFIS: 0019000052 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for Aggregate Pre-approval Program (APP). Object Code: 1025. J2 DEA: 912680. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 03/04/2020 | Sample Unique Key | 21 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 03/04/2020 |
Sample type | Aggregate Prequalification Program | A brief description of the sample | Washed Concrete Sand |
The quantity of what the sample constitutes | 150 lbs | From where was the sample collected | Source |
First name of sampler or witnessed by | Mike | Last name of sampler or witnessed by | Maldonado |
Title of sampler | QC Tech | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | 2020-03-04-14 | |
The fabricator/manufacturer/facility name | Vulcan Materials Reliance | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-19-0016::RELIANCE - IRWINDALE |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
The plant number | Unknown | A detailed description of where the material sample was collected | Unknown |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | fine |
The concrete mix design number | Unknown | Lot number | Unknown |
Sublot number | Unknown | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2020-03-04-21
DIME Test ID: 2020-03-04-21-2
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2020-08-07
Test Results
What size aggregate is being tested?: Fine Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Measured
Tester's full name: Francisco Romero
Date of test: 05/22/2020
Cumulative Mass Retained | Cumulative Percent Passing | |||||
---|---|---|---|---|---|---|
515 grams | ||||||
0 grams | 100 % | |||||
5 grams | 99 % | |||||
86 grams | 83 % | |||||
177 grams | 66 % | |||||
281 grams | 45 % | |||||
397 grams | 23 % | |||||
464 grams | 10 % | |||||
492 grams | 4 % | |||||
515 grams |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/7/2020 ✔