Summary for Test 2020-05-21-6-1

Test performed: ASTM A970-15e1

Project Information

Project IdentifiersProject ID: 213569
DEA: 024F2104
EFIS: 0212000072
DIST-CO-RTE-PM02-MOD-299-0.5/1.0
Award Date12/20/2018
Closeout Date11/15/2021
Work DescriptionButte and Ash Creek Bridge Replacement
Location DescriptionConstruction of Butte Creek Bridge and Ash Creek Bridge on Route 299 at Adin
QA Service Level1 (Verified on 06/26/2019)

Sample Information

Sample Taken Date05/21/2020 Sample Unique Key6
Date that the sample was received by the laboratory/organization performing the testing05/22/2020 Sample typeDepartment Acceptance
A brief description of the sample#10 Button Heads The quantity of what the sample constitutes27
From where was the sample collectedFabricator First name of sampler or witnessed byKevin
Last name of sampler or witnessed bymuser Title of samplerqa
Telephone number of sampler9165170532 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameCamblin
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormS19-205-20
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)4090228 Head Manufacturer Lot Number(s)A182386
Rebar Size#10 Headed Bar Model NameBNX
Size of HeadFull Size - 9x Head Connection TypeCrimped Head
Head ShapeCircular Rebar ManufacturerCMC
Head ManufacturerBarsplice Head FabricatorBarsplice BNX Buttonheads
Material Standard CodeASTM A706 Headed Bar Unique IDNot set

Test Details

DIME Sample ID: 2020-05-21-6
DIME Test ID: 2020-05-21-6-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2020-05-22

Test Results


Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 05/22/2020
UTM: 400kip
Temperature: 72 f
NumLot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
121.2712262396553Ok Neckingbewing

General comments (publicly viewable) (Max 1000 characters): Ok Necking
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 5/22/2020 ✔