Summary for Test 2020-02-12-36-6

Test performed: CTM 217-June 2011

Project Information

Project IdentifiersProject ID: 66666
DEA: APP
EFIS: 0019000052
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for Aggregate Pre-approval Program (APP). Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date02/12/2020 Sample Unique Key36
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/12/2020
Sample typeAggregate Prequalification Program A brief description of the sampleWashed Concrete Sand
The quantity of what the sample constitutes4 Bags From where was the sample collectedManufacturer
First name of sampler or witnessed byRene Last name of sampler or witnessed byMorquecho
Title of samplerQC Technician Telephone number of sampler559-416-3147
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCEMEX - Rockfield Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-10-0014::ROCKFIELD PLANT
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedStockpile
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Sizefine
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-02-12-36
DIME Test ID: 2020-02-12-36-6
Testing Lab: CEMEX - Rockfield
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2020-05-21

Test Results


Number of tests: 3
Input Type: Calculated
Tester's full name: Anthony Myers
Date of test: 02/13/2020
Temperature correction: 0
Temperature of solution: 73
Clay reading (test 1): 44
Sand reading (test 1): 37
Clay reading (test 2): 46
Sand reading (test 2): 38
Clay reading (test 3): 46
Sand reading (test 3): 39
Sand equivalent (test 1): 85
Sand equivalent (test 2): 83
Sand equivalent (test 3): 85
Sand equivalent before temperature correction: 85
Sand equivalent after temperature correction: 85
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/21/2020