Summary for Test 2020-05-08-5-4
Test performed: ASTM A370-15Project Information
| Project Identifiers | Project ID: 213485 DEA: 032F9804 EFIS: 0312000026 |
|---|---|
| DIST-CO-RTE-PM | 03-COL-20-31.7/32.9 |
| Award Date | 10/15/2018 |
| Closeout Date | 05/11/2022 |
| Work Description | PAVEMENT REHABILITATION |
| Location Description | COLUSA COUNTY IN AND NEAR COLUSA FROM 0.1 MILE EAST OF THE MARKET STREET/STATE ROUTE 20 INTERSECTION TO 0.1 MILE SOUTH OF BUTTE VISTA DRIVE |
| QA Service Level | 1 (Verified on 01/08/2019) |
Sample Information
| Sample Taken Date | 05/08/2020 | Sample Unique Key | 5 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 05/13/2020 | Sample type | Department Acceptance |
| A brief description of the sample | 2.25" x 4' 6" F1154 Gr 55 | The quantity of what the sample constitutes | 17 |
| From where was the sample collected | Source | First name of sampler or witnessed by | Armondo |
| Last name of sampler or witnessed by | Contreras | Title of sampler | QA |
| Telephone number of sampler | 949-517-8520 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | UIS | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | S60-001-20 | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | N/A |
|---|---|---|---|
| Heat Number(s) | 1201012623 | Nut Mfg. Lot Number(s) | N/A |
| Washer Mfg. Lot Number(s) | N/A | Bolt Specification | F1554 GR55 |
| Bolt Length(s) | 4' 6" | Nut Specification | N/A |
| Washer Specification | N/A | Finish | Partial HDG |
| Diameter/Size | 2.25 | Bolt Mfg. Lot Number | 120101262320 |
| Rocap Test Requirement(s) | NO | Lubricant Requirements(s) | NO |
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Test Details
DIME Sample ID: 2020-05-08-5
DIME Test ID: 2020-05-08-5-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2020-05-13
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 05/13/2020
UTM: 67kip
Temperature: 72 f
| Num | Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 2 | 1201012623 | 0.5 | 0.196 | 65015 | 93698 | 25.3 | fsaylor |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 5/13/2020 ✔