Summary for Test 2020-05-08-5-4
Test performed: ASTM A370-15Project Information
Project Identifiers | Project ID: 213485 DEA: 032F9804 EFIS: 0312000026 |
---|---|
DIST-CO-RTE-PM | 03-COL-20-31.7/32.9 |
Award Date | 10/15/2018 |
Closeout Date | 05/11/2022 |
Work Description | PAVEMENT REHABILITATION |
Location Description | COLUSA COUNTY IN AND NEAR COLUSA FROM 0.1 MILE EAST OF THE MARKET STREET/STATE ROUTE 20 INTERSECTION TO 0.1 MILE SOUTH OF BUTTE VISTA DRIVE |
QA Service Level | 1 (Verified on 01/08/2019) |
Sample Information
Sample Taken Date | 05/08/2020 | Sample Unique Key | 5 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/13/2020 |
Sample type | Department Acceptance | A brief description of the sample | 2.25" x 4' 6" F1154 Gr 55 |
The quantity of what the sample constitutes | 17 | From where was the sample collected | Source |
First name of sampler or witnessed by | Armondo | Last name of sampler or witnessed by | Contreras |
Title of sampler | QA | Telephone number of sampler | 949-517-8520 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | UIS | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | S60-001-20 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | N/A |
---|---|---|---|
Heat Number(s) | 1201012623 | Nut Mfg. Lot Number(s) | N/A |
Washer Mfg. Lot Number(s) | N/A | Bolt Specification | F1554 GR55 |
Bolt Length(s) | 4' 6" | Nut Specification | N/A |
Washer Specification | N/A | Finish | Partial HDG |
Diameter/Size | 2.25 | Bolt Mfg. Lot Number | 120101262320 |
Rocap Test Requirement(s) | NO | Lubricant Requirements(s) | NO |
Test Details
DIME Sample ID: 2020-05-08-5
DIME Test ID: 2020-05-08-5-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2020-05-13
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 05/13/2020
UTM: 67kip
Temperature: 72 f
Num | Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 2 | 1201012623 | 0.5 | 0.196 | 65015 | 93698 | 25.3 | fsaylor |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 5/13/2020 ✔