Summary for Test 2020-03-20-25-2

Test performed: CTM 217-June 2011

Project Information

Project IdentifiersProject ID: 210735
DEA: 071193U4
EFIS: 0713000007
DIST-CO-RTE-PM07-LA-10-37.2/42.4
Award Date11/16/2015
Closeout Date07/11/2022
Work DescriptionCONSTRUCT HOV LANES, WIDEN BRIDGES, AND REALIGN RAMPS.
Location DescriptionIN LA COUNTY FROM CITRUS STREET IN WEST COVINA TO ROUTE 57 IN POMONA
QA Service Level1 (Verified on 03/07/2016)

Sample Information

Sample Taken Date03/20/2020 Sample Unique Key25
Date that the sample was received by the laboratory/organization performing the testing04/10/2020 Sample typeDepartment Acceptance
A brief description of the sampleRECYCLED LEAN BASE AGG FOR LCB The quantity of what the sample constitutesna
From where was the sample collectedManufacturer First name of sampler or witnessed byG
Last name of sampler or witnessed byZUBIETA Title of samplerTET
Telephone number of sampler Laboratory sample identification9698
Linked DIME Sample ID The fabricator/manufacturer/facility nameATKINSON PORTABLE PLANT POMONA
Transportation Laboratory (TL) Number9233382 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)00-00-0000
The fabricator's/manufacturer's product name for the sampleLCB The fabricator/manufacturer designation for the sampleLB20-0006 AGGREGATE
The plant numberUnknown A detailed description of where the material sample was collectedNA
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1 inch
The concrete mix design numberLB20-0006 Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-03-20-25
DIME Test ID: 2020-03-20-25-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2020-05-13

Test Results


Number of tests: 2
Input Type: Calculated
Tester's full name: Larry Diaz
Date of test: 04/16/2020
Temperature correction: 0
Temperature of solution: 72
Clay reading (test 1): 6.6
Sand reading (test 1): 4
Clay reading (test 2): 6.8
Sand reading (test 2): 4
Sand equivalent (test 1): 61
Sand equivalent (test 2): 59
Sand equivalent before temperature correction: 60
Sand equivalent after temperature correction: 60
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/13/2020 ✔