Summary for Test 2020-04-10-7-10
Test performed: ASME B1.2-83r01Project Information
Project Identifiers | Project ID: 208945 DEA: 07288604 EFIS: 0700021080 COOP: 074663 |
---|---|
DIST-CO-RTE-PM | 07-LA-710-6.0-9.4 |
Award Date | 09/02/2011 |
Closeout Date | Not set |
Work Description | Gerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing. |
Location Description | Port of Long Beach (District 7) |
QA Service Level | 1 (Verified on 06/03/2013) |
Sample Information
Sample Taken Date | 04/10/2020 | Sample Unique Key | 7 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/10/2020 |
Sample type | Independent Assurance | A brief description of the sample | ASTM F1554 Gr 55 Anchor Bolt with nut and washer |
The quantity of what the sample constitutes | 4 Anchor Bolt Assemblies | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Andrew | Last name of sampler or witnessed by | Webster |
Title of sampler | IQA FIELD INSPECTOR | Telephone number of sampler | 925-418-9838 |
Laboratory sample identification | Linked DIME Sample ID | 2018-04-05-1, 2019-04-16-1 | |
The fabricator/manufacturer/facility name | Universal Industrial Sales | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B201-009-20 | Structure unique identifier | |
Structure name | GDB |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | PL17100835, 188194, B916323 | Nut Mfg. Lot Number(s) | DDYO |
Washer Mfg. Lot Number(s) | D7581 | Bolt Specification | ASTM F1554 GR 55 |
Bolt Length(s) | 2'-2" | Nut Specification | ASTM A153/F2329 per ASTM A563 Grade DH, ASTM A194 Grade 2H |
Washer Specification | ASTM F436, ASTM F844 | Finish | hot dip galvanizing HDG |
Diameter/Size | 2" | Bolt Mfg. Lot Number | PL1710083501 |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2020-04-10-7
DIME Test ID: 2020-04-10-7-10
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Test Release Date: 2020-05-08
Test Results
Input Type: Calculated
Tester's full name: Fred Saylor
Date of test: 05/08/2020
Sample No.: 1E
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: DDYO
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: 2H DH D/N
Size: 2 in
Gage Type: Pass
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/8/2020 ✔