Summary for Test 2020-03-05-20-1
Test performed: CTM 202-November 2011Project Information
| Project Identifiers | Project ID: 66666 DEA: APP EFIS: 0019000052 |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for submitting Sample information for Aggregate Pre-approval Program (APP). Object Code: 1025. J2 DEA: 912680. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 03/05/2020 | Sample Unique Key | 20 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/08/2020 |
| Sample type | Aggregate Prequalification Program | A brief description of the sample | Washed Concrete Sand |
| The quantity of what the sample constitutes | production stockpile. | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Owen |
| Title of sampler | Quality Control Supervisor | Telephone number of sampler | 209-481-2952 |
| Laboratory sample identification | Linked DIME Sample ID | 20-3-5-14 | |
| The fabricator/manufacturer/facility name | Santa Fe Kaweah South | Transportation Laboratory (TL) Number | 20-APPF-0051 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-54-0036::KAWEAH SOUTH |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
| The plant number | Unknown | A detailed description of where the material sample was collected | Stockpile at the Plant |
| Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | fine |
| The concrete mix design number | Unknown | Lot number | Unknown |
| Sublot number | Unknown | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2020-03-05-20
DIME Test ID: 2020-03-05-20-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2020-05-06
Test Results
What size aggregate is being tested?: Fine Aggregate
Individual or cumulative mass retained on each sieve?: Individual Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Measured
Tester's full name: Jay Horton
Date of test: 04/29/2020
| Sieve Size | Individual Mass Retained | Cumulative Percent Passing | ||||
|---|---|---|---|---|---|---|
| 487 grams | ||||||
| 0.0 grams | 100 % | |||||
| 12.4 grams | 97 % | |||||
| 126.4 grams | 71 % | |||||
| 116.1 grams | 48 % | |||||
| 90.9 grams | 29 % | |||||
| 70.1 grams | 15 % | |||||
| 47.1 grams | 5 % | |||||
| 23.4 grams | 0 % | |||||
| 0.6 grams | ||||||
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/6/2020 ✔