Summary for Test 2020-05-01-6-2
Test performed: ASTM A416-15Project Information
| Project Identifiers | Project ID: 213229 DEA: 050A0504 EFIS: 0500000007 |
|---|---|
| DIST-CO-RTE-PM | 05-SB-1-15.6 |
| Award Date | 12/14/2018 |
| Closeout Date | 08/17/2022 |
| Work Description | BRIDGE REPLACEMENT, RETAINING WALL AND FISH PASSAGE. |
| Location Description | SANTA BARBARA COUNTY NEAR LOMPOC AT SALSIPUEDES CREEK BRIDGE |
| QA Service Level | 1 (Verified on 03/23/2018) |
Sample Information
| Sample Taken Date | 05/01/2020 | Sample Unique Key | 6 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 05/11/2020 |
| Sample type | Quality Assurance | A brief description of the sample | (1) .6"Ø 4 ft. Long |
| The quantity of what the sample constitutes | (1 pack) .6"Ø 8,714 ft. Long | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Rigoberto | Last name of sampler or witnessed by | Marin |
| Title of sampler | QA | Telephone number of sampler | 951-500-0685 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | OLDCAST PRECAST PERRIS | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L133-075-20 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM4 - Prestressing Strand | Comments | |
|---|---|---|---|
| Reel/Coil/Pack Number(s) | S379038-2 | Number of Coils | 1 |
| Group Number | Strand Diameter | .6 in | |
| Grade | 270 | Strand Specification | ASTM A 416 |
| Heat Number(s) | S0541520 | Mfg. Lot Number(s) | S379038-2 |
| Manufacturer(s) | Sumiden Wire |
Test Details
DIME Sample ID: 2020-05-01-6
DIME Test ID: 2020-05-01-6-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2020-05-06
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 05/05/2020
UTM: 120kip
Temperature: 72 f
Extensometers: no data
| Num | Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | S0541520 | S379038-2 | 0.214 | 59878 | 55778.1 | 28.5 | 1.73 | bewing |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 5/6/2020 ✔