Summary for Test 2019-12-01-25-1
Test performed: CTM 202-November 2011Project Information
| Project Identifiers | Project ID: 66666 DEA: APP EFIS: 0019000052 |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for submitting Sample information for Aggregate Pre-approval Program (APP). Object Code: 1025. J2 DEA: 912680. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 12/01/2019 | Sample Unique Key | 25 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/06/2020 |
| Sample type | Aggregate Prequalification Program | A brief description of the sample | Concrete agg 3/8" Crushed |
| The quantity of what the sample constitutes | 2 buckets | From where was the sample collected | Source |
| First name of sampler or witnessed by | Jordan | Last name of sampler or witnessed by | Baker |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | 20-APPC-0043 - retest 20-APPC-0061 from new sample | Linked DIME Sample ID | 2019-12-01-2 |
| The fabricator/manufacturer/facility name | Deer Creek Rock and Aspahlt | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-54-0021::DEER CREEK ASPHALT |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
| The plant number | Unknown | A detailed description of where the material sample was collected | Stockpile sample by loader bucket |
| Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 3/8 inch |
| The concrete mix design number | Unknown | Lot number | Unknown |
| Sublot number | Unknown | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2019-12-01-25
DIME Test ID: 2019-12-01-25-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2020-05-01
Test Results
What size aggregate is being tested?: 0.375 in x No. 8 - Coarse Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Measured
Tester's full name: Ryan Kester
Date of test: 04/07/2020
| Sieve Size | Cumulative Mass Retained | Cumulative Percent Passing | ||||
|---|---|---|---|---|---|---|
| 1027.1 grams | ||||||
| 0.0 grams | 100 % | |||||
| 54.1 grams | 95 % | |||||
| 698.4 grams | 32 % | |||||
| 982.5 grams | 4 % | |||||
| 1027.1 grams | ||||||
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/1/2020 ✔