Summary for Test 2020-04-02-19-1

Test performed: ASTM C39-17a

Project Information

Project IdentifiersProject ID: 214221
DEA: 081F1424
EFIS: 0815000232
DIST-CO-RTE-PM08-RIV-15-23.9/33.4
Award Date09/05/2019
Closeout Date03/01/2022
Work DescriptionREPLACE INDIVIDUAL PCC SLABS, GRIND PCC PAVEMENT AND UPGRADE GUARDRAIL
Location DescriptionRIVERSIDE COUNTY NEAR LAKE ELSINORE FROM NICHOLS ROAD OVERCROSSING TO 0.2 MILE NORTH OF TEMESCAL CANYON ROAD UNDERCROSSING
QA Service Level1 (Verified on 12/04/2019)

Sample Information

Sample Taken Date04/02/2020 Sample Unique Key19
Date that the sample was received by the laboratory/organization performing the testing04/04/2020 Sample typeQuality Assurance
A brief description of the sampleCONCRETE CYLINDERS The quantity of what the sample constitutes4 CY
From where was the sample collectedJob Site First name of sampler or witnessed byKEVIN
Last name of sampler or witnessed byCHAN Title of samplerTET
Telephone number of sampler Laboratory sample identification1010-01
Linked DIME Sample ID The fabricator/manufacturer/facility nameNA
Transportation Laboratory (TL) Number01 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberNA
The truck number from where the sample was collected1 The batch plant ticket number from where the sample was collected107
Concrete batch plantNA The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedNA Where the material sample would have been placed if not sampledGALIVAN LAKE ST TEMESCAL CANYON
From Lot No.Unknown Bag Lot No.Unknown

Test Details

DIME Sample ID: 2020-04-02-19
DIME Test ID: 2020-04-02-19-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2020-04-30

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 04/30/2020
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.01 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 43250 lb
Maximum load on cylinder 2: 43680 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 28 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.37 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength of cylinder 1: 1524.5 psi
Compressive strength of cylinder 2: 1545.1 psi
Compressive strength (to nearest 10 psi): 1530 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/30/2020 ✔