Summary for Test 2020-04-14-10-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 214587
DEA: 101J1604
EFIS: 1018000180
DIST-CO-RTE-PM10-STA-132-27.9/41.0
Award Date03/02/2020
Closeout Date04/26/2021
Work DescriptionCOLD PLANE AC PAVEMENT, RHMA OVERLAY AND SLURRY SEAL.
Location DescriptionSTANISLAUS COUNTY IN AND NEAR WATERFORD FROM G STREET TO 1.2 MILES EAST OF RUSHING ROAD
QA Service Level1 (Verified on 01/24/2020)

Sample Information

Sample Taken Date04/14/2020 Sample Unique Key10
Date that the sample was received by the laboratory/organization performing the testing04/15/2020 Sample typeVerification
A brief description of the sampleVirgin aggregate for 3/4 Type A HMA mix The quantity of what the sample constitutesBags of Aggregate for JMF
From where was the sample collectedSource First name of sampler or witnessed byJ
Last name of sampler or witnessed byKort Title of samplerTechnician
Telephone number of sampler Laboratory sample identification20-JMF-0044
Linked DIME Sample ID The fabricator/manufacturer/facility nameGeorge Reed Inc
Transportation Laboratory (TL) NumberC033877 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-55-0005::TABLE MOUNTAIN QUARRY
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedPlant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-04-14-10
DIME Test ID: 2020-04-14-10-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2020-04-27

Test Results


What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: No
Input Type: Measured
Tester's full name: Ryan Kester
Date of test: 04/17/2020
Cumulative Mass RetainedCumulative Percent Passing
5223.7 grams
grams %
0.0 grams100 %
0.0 grams100 %
245.2 grams95.3 %
650.7 grams87.5 %
1093.8 grams79.1 %
2525.8 grams51.6 %
213.7 grams35.3 %
365.3 grams23.7 %
470.4 grams15.6 %
558.1 grams8.9 %
606.3 grams5.2 %
631.6 grams3.3 %
grams
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/27/2020