Summary for Test 2020-04-20-5-7
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 213411 DEA: 030H10U4 EFIS: 0317000246 |
|---|---|
| DIST-CO-RTE-PM | 03-SAC-5-9.7/24.9 |
| Award Date | 05/01/2019 |
| Closeout Date | 02/22/2024 |
| Work Description | Not set |
| Location Description | Construction on state highway in Sacramento County in and near Sacramento from 1.1 miles south of Elk Grove Boulevard to American River Viaduct |
| QA Service Level | 1 (Verified on 07/19/2019) |
Sample Information
| Sample Taken Date | 04/20/2020 | Sample Unique Key | 5 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 04/22/2020 | Sample type | Quality Assurance |
| A brief description of the sample | Flash Welded Hoops | The quantity of what the sample constitutes | 1350 |
| From where was the sample collected | Source | First name of sampler or witnessed by | PRakash |
| Last name of sampler or witnessed by | Patel | Title of sampler | TET |
| Telephone number of sampler | (562)665-4686 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | TNT Rebar | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | L11-001-20 | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Service | Rebar Heat Number(s) | 3500010786 |
| Hoop Manufacturer Lot Number(s) | 106R67, 109R72, 113R90 | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Size | #5 |
| Diameter of Hoop | 1'-2" | Epoxy Coated | No |
| Epoxy Coating Color | NA | Rebar Manufacturer | Nucor |
| Welding Company | TNT Rebar | Coating Standards | Uncoated |
| Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2020-04-20-5
DIME Test ID: 2020-04-20-5-7
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2020-04-24
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 04/24/2020
UTM: 400kip
Temperature: 72 f
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1 | 109R72 | 5/16mm | 0.31 | 30668.16 | 98930 | Ok Necking | bewing |
General comments (publicly viewable) (Max 1000 characters): Ok Necking
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 4/24/2020 ✔