Summary for Test 2020-03-26-14-1
Test performed: ASTM C39-10Project Information
| Project Identifiers | Project ID: 214176 DEA: 033F0904 EFIS: 0312000056 |
|---|---|
| DIST-CO-RTE-PM | 03-SAC,SJ-5,160-Var |
| Award Date | 10/10/2019 |
| Closeout Date | 10/27/2022 |
| Work Description | REPLACE STRUCTURAL CONCRETE BRIDGES, PLACE CIDH & CISS CONCRETE PILES. |
| Location Description | SACRAMENTO COUNTY AT NORTH SACRAMENTO UNDERCROSSING AND SACRAMENTO RIVER BRIDGE AND IN SAN JOAQUIN COUNTY AT MOKELUMNE RIVER BRIDGE |
| QA Service Level | 1 (Verified on 05/29/2019) |
Sample Information
| Sample Taken Date | 03/26/2020 | Sample Unique Key | 14 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/27/2020 |
| Sample type | Quality Assurance | A brief description of the sample | 6x12 concrete cylinders |
| The quantity of what the sample constitutes | 5 cylinders | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Chuck | Last name of sampler or witnessed by | Pazzi |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Jobsite | Transportation Laboratory (TL) Number | 173235 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | 1615758 |
|---|---|---|---|
| The truck number from where the sample was collected | Unknown | The batch plant ticket number from where the sample was collected | 00000000000000000 |
| Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
| A detailed description of where the material sample was collected | Jobsite | Where the material sample would have been placed if not sampled | Unknown |
| From Lot No. | Unknown | Bag Lot No. | Unknown |
Test Details
DIME Sample ID: 2020-03-26-14
DIME Test ID: 2020-03-26-14-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2020-04-23
Test Results
Unit system used?: US Units
Number of specimens: 5
Test performed: With no density determined
Input Type: Measured
Tester's full name: LMC / PM
Date of test: 04/23/2020
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.02 in
Average diameter of cylinder 2: 6.02 in
Average diameter of cylinder 3: 6.02 in
Average diameter of cylinder 4: 6.01 in
Average diameter of cylinder 5: 6.02 in
Maximum load on cylinder 1: 276017 lbf
Maximum load on cylinder 2: 273695 lbf
Maximum load on cylinder 3: 272815 lbf
Maximum load on cylinder 4: 261941 lbf
Maximum load on cylinder 5: 269034 lbf
Type of fracture pattern of cylinder 1: 4
Type of fracture pattern of cylinder 2: 4
Type of fracture pattern of cylinder 3: 4
Type of fracture pattern of cylinder 4: 4
Type of fracture pattern of cylinder 5: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Correction factor for cylinder 4: 1.00
Correction factor for cylinder 5: 1.00
Age of specimen: 28 days
Cross sectional area of cylinder 1: 28.46 in^2
Cross sectional area of cylinder 2: 28.46 in^2
Cross sectional area of cylinder 3: 28.46 in^2
Cross sectional area of cylinder 4: 28.37 in^2
Cross sectional area of cylinder 5: 28.46 in^2
Compressive strength of cylinder 1: 9697.0 psi
Compressive strength of cylinder 2: 9616.0 psi
Compressive strength of cylinder 3: 9585.0 psi
Compressive strength of cylinder 4: 9233.0 psi
Compressive strength of cylinder 5: 9452.0 psi
Compressive strength (to nearest 10 psi): 9520 psi
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point FileTest graph for Cylinder Code 1 of 5
Source: Bluehill Data Point File
Test graph for Cylinder Code 2 of 5
Source: Bluehill Data Point File
Test graph for Cylinder Code 3 of 5
Source: Bluehill Data Point File
Test graph for Cylinder Code 4 of 5
Source: Bluehill Data Point File
Test graph for Cylinder Code 5 of 5
Test was verified on 4/23/2020 ✔