Summary for Test 2014-01-22-15109181-1
Test performed: CTM 202-November 2011Project Information
| Project Identifiers | Project ID: 7051 DEA: 023E9304 |
|---|---|
| DIST-CO-RTE-PM | 02-TRI,TRI-299-0.0/0.1,64.0/72.2 |
| Award Date | 04/11/2012 |
| Closeout Date | 06/21/2013 |
| Work Description | HMA THIN BLANKET OVERLAY WITH DIGOUTS |
| Location Description | SHASTA AND TRINITY COUNTIES AT AND NEAR DOUGLAS CITY FROM 0.5 MILE EAST OF LEWISTON ROAD TO 0.1 MILE EAST OF SHASTA COUNTY LINE |
| QA Service Level | 1 (Verified on 03/29/2012) |
Sample Information
| Sample Taken Date | 01/22/2014 | Sample Unique Key | 15109181 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 01/22/2014 | Sample type | Per Request |
| A brief description of the sample | Type A aggregate extracted by ignition | The quantity of what the sample constitutes | 4 Cores |
| From where was the sample collected | Other | First name of sampler or witnessed by | Terry |
| Last name of sampler or witnessed by | McCormick | Title of sampler | Unknown |
| Telephone number of sampler | Unknown | Laboratory sample identification | D75699 |
| Linked DIME Sample ID | 0 | The fabricator/manufacturer/facility name | In Place FMFC HMA |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Tullis - Northstate Asphalt |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
| The plant number | Unknown | A detailed description of where the material sample was collected | TRI 299 pm 68 |
| Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | |
| The concrete mix design number | Lot number | Not set | |
| Sublot number | Not set | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2014-01-22-15109181
DIME Test ID: 2014-01-22-15109181-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2014-11-03
Test Results
What size aggregate is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Terry McCormick
Date of test: 02/04/2014
| Sieve Size | Cumulative Percent Passing | |||||
|---|---|---|---|---|---|---|
| 100 % | ||||||
| 100 % | ||||||
| 100 % | ||||||
| 100 % | ||||||
| 100 % | ||||||
| 100 % | ||||||
| 98 % | ||||||
| 89 % | ||||||
| 58 % | ||||||
| 37 % | ||||||
| 25 % | ||||||
| 19 % | ||||||
| 14 % | ||||||
| 10 % | ||||||
| 8.1 % | ||||||
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/3/2014 ✔