Summary for Test 2014-01-22-15109181-1

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 7051
DEA: 023E9304
DIST-CO-RTE-PM02-TRI,TRI-299-0.0/0.1,64.0/72.2
Award Date04/11/2012
Closeout Date06/21/2013
Work DescriptionHMA THIN BLANKET OVERLAY WITH DIGOUTS
Location DescriptionSHASTA AND TRINITY COUNTIES AT AND NEAR DOUGLAS CITY FROM 0.5 MILE EAST OF LEWISTON ROAD TO 0.1 MILE EAST OF SHASTA COUNTY LINE
QA Service Level1 (Verified on 03/29/2012)

Sample Information

Sample Taken Date01/22/2014 Sample Unique Key15109181
Date that the sample was received by the laboratory/organization performing the testing01/22/2014 Sample typePer Request
A brief description of the sampleType A aggregate extracted by ignition The quantity of what the sample constitutes4 Cores
From where was the sample collectedOther First name of sampler or witnessed byTerry
Last name of sampler or witnessed byMcCormick Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationD75699
Linked DIME Sample ID0 The fabricator/manufacturer/facility nameIn Place FMFC HMA
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Tullis - Northstate Asphalt
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedTRI 299 pm 68
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size
The concrete mix design number Lot numberNot set
Sublot numberNot set Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2014-01-22-15109181
DIME Test ID: 2014-01-22-15109181-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2014-11-03

Test Results


What size aggregate is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Terry McCormick
Date of test: 02/04/2014
Sieve SizeCumulative Percent Passing
100 %
100 %
100 %
100 %
100 %
100 %
98 %
89 %
58 %
37 %
25 %
19 %
14 %
10 %
8.1 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/3/2014 ✔