Summary for Test 2020-03-20-20-3
Test performed: AASHTO T209-12Project Information
| Project Identifiers | Project ID: 213469 DEA: 024C40V4 EFIS: 0218000125 |
|---|---|
| DIST-CO-RTE-PM | 02-SHA-5-R3.8/R11.7 |
| Award Date | 11/06/2018 |
| Closeout Date | 08/16/2023 |
| Work Description | WIDEN TO 6 LANES, BRIDGE REPLACEMENT AND WIDENING AND ROADWAY REHAB |
| Location Description | SHASTA COUNTY IN AND NEAR ANDERSON FROM ROUTE 5/273 SEPARATION TO 0.4 MILE SOUTH OF CHURN CREEK ROAD OVERCROSSING |
| QA Service Level | 1 (Verified on 12/31/2018) |
Sample Information
| Sample Taken Date | 03/20/2020 | Sample Unique Key | 20 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 03/23/2020 | Sample type | Department Acceptance |
| A brief description of the sample | RAP | The quantity of what the sample constitutes | 50000 ton |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Karen |
| Last name of sampler or witnessed by | Spliethof | Title of sampler | TET |
| Telephone number of sampler | Laboratory sample identification | D78363B | |
| Linked DIME Sample ID | 2020-03-20-19 | The fabricator/manufacturer/facility name | Fawndale Rock and Asphalt - Redding, CA |
| Transportation Laboratory (TL) Number | 897551 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Reclaimed Asphalt Pavement | RAP Source | Fawndale Rock and Asphalt, Redding, CA |
|---|---|---|---|
| Aggregate Size | 3/8-inch | Aggregate Source | Unknown |
| RAP Stockpile | Stockpile Size (tons) | Unknown | |
| Reclaimed Asphalt Pavement Mix Number | Not set |
Test Details
DIME Sample ID: 2020-03-20-20
DIME Test ID: 2020-03-20-20-3
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2020-04-14
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Darrell Valasek
Date of test: 03/26/2020
Method Performed: no data
Mass of container filled with water: 7338 grams
Mass of oven-dry sample in air for Sample 1: 1733 grams
Mass of container filled with the sample and water for Sample 1: 8390 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.544
Theoretical maximum density at 25°C (77°F): no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/14/2020 ✔