Summary for Test 2020-04-10-5-6

Test performed: ASTM A970-15e1

Project Information

Project IdentifiersProject ID: 213411
DEA: 030H10U4
EFIS: 0317000246
DIST-CO-RTE-PM03-SAC-5-9.7/24.9
Award Date05/01/2019
Closeout Date02/22/2024
Work DescriptionNot set
Location DescriptionConstruction on state highway in Sacramento County in and near Sacramento from 1.1 miles south of Elk Grove Boulevard to American River Viaduct
QA Service Level1 (Verified on 07/19/2019)

Sample Information

Sample Taken Date04/10/2020 Sample Unique Key5
Date that the sample was received by the laboratory/organization performing the testing04/22/2020 Sample typeQuality Assurance
A brief description of the sampleHRC 555 Headed Reinforcement The quantity of what the sample constitutes440
From where was the sample collectedFabricator First name of sampler or witnessed bySherri
Last name of sampler or witnessed byBrannon Title of samplerMETS QA inspector
Telephone number of sampler916-826-6371 Laboratory sample identification
Linked DIME Sample IDLots 1 and 3 The fabricator/manufacturer/facility nameCamblin Steel Service, Benicia
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormB22-016-20
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)073120 Head Manufacturer Lot Number(s)Lots 1 through 3
Rebar Size#10 Headed Bar Model NameHRC 555
Size of HeadReduced Size - 4x Head Connection TypeInertia Weld
Head ShapeCircular Rebar ManufacturerCascade Steel
Head ManufacturerCamblin Steel Service Head FabricatorCamblin Steel Service
Material Standard CodeASTM A706 Headed Bar Unique IDNot set

Test Details

DIME Sample ID: 2020-04-10-5
DIME Test ID: 2020-04-10-5-6
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2020-04-16

Test Results


Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 04/14/2020
UTM: 400kip
Temperature: 72 f
NumLot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
131.2711956494145Ok Neckingbewing

General comments (publicly viewable) (Max 1000 characters): Ok Necking
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 4/16/2020