Summary for Test 2020-03-23-6-2

Test performed: AASHTO T96-02r10

Project Information

Project IdentifiersProject ID: 213579
DEA: 051C2504
EFIS: 0512000107
DIST-CO-RTE-PM05-MON-68-1.6/L4.1
Award Date02/19/2019
Closeout Date08/23/2021
Work DescriptionSHOULDER WIDENING, RUMBLE STRIPS, STRIPING, AND UPGRADE GUARDRAIL.
Location DescriptionMONTEREY COUNTY IN AND NEAR MONTEREY AT VARIOUS LOCATIONS FROM 0.1 MILE EAST OF PIEDMONT AVENUE TO 0.1 MILE EAST OF SCENIC DRIVE OVERCROSSING
QA Service Level1 (Verified on 09/06/2019)

Sample Information

Sample Taken Date03/23/2020 Sample Unique Key6
Date that the sample was received by the laboratory/organization performing the testing03/25/2020 Sample typeVerification
A brief description of the sampleBags of Aggregate The quantity of what the sample constitutesOne JMF Verification
From where was the sample collectedManufacturer First name of sampler or witnessed byAnthony
Last name of sampler or witnessed byRomiza Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameGranite Salinas
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-27-0028::HANDLEY RANCH QUARRY
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedAt the Plant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1/2 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-03-23-6
DIME Test ID: 2020-03-23-6-2
Testing Lab: CT D05 - San Luis Obispo District Laboratory
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Test Release Date: 2020-04-09

Test Results


Input Type: Calculated
Tester's full name: Daniel Gingras
Date of test: 04/02/2020
Grading designation: C
Percent loss after 100 revolutions: 7 %
Percent loss after 500 revolutions: 30 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/9/2020 ✔