Summary for Test 2020-04-01-3-1
Test performed: ASTM F606-14aProject Information
| Project Identifiers | Project ID: 210037 DEA: 043G4424 EFIS: 0412000042 |
|---|---|
| DIST-CO-RTE-PM | 04-SF-80-R5.6/7.6 |
| Award Date | 03/22/2018 |
| Closeout Date | 07/24/2023 |
| Work Description | WEST SPAN DAMPER BRACKET A325 BOLT TESTING |
| Location Description | SFOBB WEST SPAN |
| QA Service Level | 1 (Verified on 11/04/2014) |
Sample Information
| Sample Taken Date | 04/01/2020 | Sample Unique Key | 3 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/06/2020 |
| Sample type | Quality Assurance | A brief description of the sample | A325 Fasteners |
| The quantity of what the sample constitutes | 310 ea | From where was the sample collected | Distributor |
| First name of sampler or witnessed by | Greg | Last name of sampler or witnessed by | Thompson |
| Title of sampler | Associate Steel Inspector | Telephone number of sampler | 510-376-7155 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Bay Bolt | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | B9-022-20 | Structure unique identifier | |
| Structure name | SFOBB | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 1188-01 |
|---|---|---|---|
| Heat Number(s) | bolt-10629590 washer- 163050 nut- DL18104889 | Nut Mfg. Lot Number(s) | Nut- 416921B |
| Washer Mfg. Lot Number(s) | Washer- 141843 | Bolt Specification | A325 |
| Bolt Length(s) | 3 1/2" | Nut Specification | F563 |
| Washer Specification | F436 | Finish | Galv |
| Diameter/Size | 1" | Bolt Mfg. Lot Number | L569M1 |
| Rocap Test Requirement(s) | yes | Lubricant Requirements(s) | yes |
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2020-04-01-3
DIME Test ID: 2020-04-01-3-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2020-04-09
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 04/08/2020
UTM: 450kip
Temperature: no data
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1 | L569M1 | 1.0000 | 90989 | 404.74 | 10.00 | A325 Bolt | fsaylor |
General comments (publicly viewable) (Max 1000 characters): A325 Bolt
Test Graph
Source: Bluehill Data Point FileTest was verified on 4/9/2020 ✔