Summary for Test 2020-02-14-25-1
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 214520 DEA: 051H9804 EFIS: 0517000043 |
|---|---|
| DIST-CO-RTE-PM | 05-SB-101-78.4/79.0 |
| Award Date | 01/08/2020 |
| Closeout Date | 09/25/2020 |
| Work Description | ROADWAY EXCAVATION, PLACE AGGREGATE BASE, HMA AND RHMA-G. |
| Location Description | SANTA BARBARA COUNTY NEAR SANTA MARIA FROM 0.3 MILE SOUTH TO 0.3 MILE NORTH OF SOLOMON SUMMIT UNDERCROSSING |
| QA Service Level | 1 (Verified on 02/20/2020) |
Sample Information
| Sample Taken Date | 02/14/2020 | Sample Unique Key | 25 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 02/14/2020 | Sample type | Quality Control |
| A brief description of the sample | Combined RAP | The quantity of what the sample constitutes | 4 Bags |
| From where was the sample collected | Source | First name of sampler or witnessed by | Daniel |
| Last name of sampler or witnessed by | Ortega | Title of sampler | Lab Supervisor |
| Telephone number of sampler | 805-345-3425 | Laboratory sample identification | 755727192 |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | CalPortland Garey Hot Plant | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Reclaimed Asphalt Pavement | RAP Source | Garey Hot Plant |
|---|---|---|---|
| Aggregate Size | Unknown | Aggregate Source | Unknown |
| RAP Stockpile | Static | Stockpile Size (tons) | Unknown |
| Reclaimed Asphalt Pavement Mix Number | Not set |
Test Details
DIME Sample ID: 2020-02-14-25
DIME Test ID: 2020-02-14-25-1
Testing Lab: CalPortland
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2020-04-03
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Ryan Deveraux
Date of test: 02/14/2020
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1554.9 g
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): no data %
Moisture Content: 0.00 %
Temperature Compensation Factor: no data
Test Temperature: 1000 F
Corrected Asphalt Binder Content: 7.49 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/3/2020 ✔